- Product Categories
- Friendly Links
| Information Name: | Supply of specific surface area tester (Beijing surface area analyzer) |
| Published: | 2012-02-13 |
| Validity: | 999 |
| Specifications: | GC5890S |
| Quantity: | 1.00 |
| Price Description: | 0 Taiwan |
| Detailed Product Description: | Jie Analytical Instruments Co., Ltd. Shanghai Branch Nanjing Branch Jie Analytical Instruments Co., Ltd. Shanghai Branch, specializing in the production surface area tester, gas chromatography, liquid chromatography, surface area analyzer. GC5890S automatic nitrogen adsorption specific surface area tester Features are summarized: The only integrated with in situ heating blowing device; and purge procedures with timing function; Programmable calibration of six-way valve system, the only quantitative control the volume at home and abroad program control switching function; With the only nitrogen pressure chromatography system, the only precision 0.01%; Has the domestic first and only hot air to help de-program-controlled system; With the only function of the gas purification cold trap so that gas purity more than 10 times; A national initiative and the only constant temperature thermal conductivity detector system; The only model with a particle size in the estimation of data processing functions, and gives the report size estimates; Instrument parameters large-screen LCD 5-inch LCD; The only liquid nitrogen with a temperature monitoring function; The only detector with gas source switching instructions and protection devices; GC5890S nitrogen adsorption specific surface area of automatic test instrument performance parameters: Test method: versatility of multi-point method can be BET, BET single point method, Langmuir multi-point method, Langmuir single-point method, solid standard reference method, such as testing sample thickness of Statistics Act (calculated outer surface area), particle size estimation sample BET adsorption constant C, such as testing methods; 3H-2000A Precision: high precision, good reproducibility. BET multi-point method, BET single point method, Langmuir multi-point method, Langmuir single-point method, testing the relative error of less than ± 2%; solid standard reference method test sample relative error of less than ± 1.5%; Test Range: test a wide range of specific surface area can be determined in 0.01m2 / g within the scope of the above substances, substances and meet all the powder surface area porous materials testing; Sample Type: Powder fiber and sheet materials. Test Time: Test Time: BET multi-point method can test four samples at the same time, the test and the average speed for each sample point for each determination of partial pressure for about 5 minutes total for each sample with an average of about 30min; BET single point method while test 4 samples measured for each sample tested and the average speed for about 5 minutes; solid standard sample reference method to test three samples while the average time for each sample measured about 6 minutes abroad, only a quarter of similar equipment test time; more of these tests Time does not include pre-purification sample purge time. Purge processing: with the only integrated degassing device (non-split), to solve the degassing, test integration, to achieve the sample in situ treatment with a single installation, with zero contact with air to ensure that the sample the efficiency and effectiveness of pretreatment; 3H-2000A Thermal Aid of wind: wind-heat with the only help de-program-controlled device, guaranteed fast sharp desorption peak, reducing the background error; Quantitative management program-controlled switching: a program-controlled six-way valve is the only calibration system, the action cycle of less than 10 milliseconds; and to quantify the volume control program-controlled switching; Inhibition of zero-drift detector: the only detector with a constant temperature system, the detector is less than 0.1mV 10min drift test results to ensure the accuracy and stability; Concentration of chromatography: the only chromatography with nitrogen partial pressure detection system, the relative flow method accuracy by 10 times, the nitrogen concentration of control accuracy and precision are up to ten thousandth, high stability; Size model estimation: Estimating size with the only data processing functions, and gives size estimates report; this function is given according to the specific surface area of each model, the average particle size, particle shape on to play a guiding researchers to determine effect; Gas Purification cold trap: the only gas purification with a cold trap so that the number of gas purity level and above increased by 1; Gas source switching protection: the only gas source switching with instructions and protection devices, breathe off automatically expire permanently avoid misuse charged for damage to the detector; Purge time: purge with the only timing, timing accuracy of 1 second. Countdown to automatically cut off after the heating power, and voice prompts; Temperature monitoring: monitoring of elimination of liquid nitrogen temperature of liquid nitrogen temperature difference between the impact of general industrial use broad; room temperature monitoring the elimination of environmental temperature. Test Accessories: standard high-purity He, high purity N2 gas mixture of nitrogen and helium 3 bottles of gas average gas use for longer than 2 years; Shanghai Branch Jie sample tube to ensure the accuracy of the test tube also makes the kind of convenience sample is not limited to powder samples in the test; 3H-2000A Control system: automatic process control adsorption and desorption process of various important aspects of voice prompts; equipment operator for the operation of other work or leave, do not worry delayed test; 3H-2000A Test stability: 5 inch LCD large-screen liquid crystal display indicates the various mechanical parts of the movement parameters of the instrument working status of software, hardware, the software also shows that even accurate information can not open the instrument state, makes the instrument a higher degree of stability; Test gas: low-temperature nitrogen adsorption dynamic chromatography, a unique parallel gas line at home and abroad, eliminating the environmental temperature, humidity, atmospheric pressure, outside influence, no vacuum, laboratory conditions require relatively relaxed; 3H-2000A Data processing: software for the self-developed high-precision data processing systems, high sampling frequency of 100Hz, 3H-2000A Automatic control; a functional surface area of data processing capabilities; USB communication interface; Instrument Hardware: Hardware components with a stable and durable, the key parts are all imported parts, after rigorous testing, suitable for frequent testing; GC5890S series of specific surface area tester main functions and application: There are chemical industry, such as petrochemical, pharmaceutical, food, agriculture, fine chemicals; Environmental areas, such as activated carbon, molecular sieve, activated alumina, etc.; Coatings, plastics industry, such as inorganic pigments, calcium carbonate, zinc oxide, silica, etc.; Ceramic materials, such as alumina, zirconia, yttria, silicon nitride, etc.; Rubber and plastic materials industry, such as carbon black, silica, calcium carbonate, etc.; New battery materials industry, such as lithium cobalt oxide, lithium manganese oxide, graphite electrode materials; powder powder fields. GC5890S automated nitrogen adsorption specific surface area tester after-sales service: I units of the instruments sold by the laws of the state law, the implementation of product repair, replacement or return. Equipment are one year warranty and lifetime maintenance, maintenance. Free installation and commissioning, training of operators. After the call and timely response. If necessary, timely door to solve the problem. Section McNair service advantages: 1, Section McNair service engineers trained in analytical chemistry, instrument repair and maintenance of professional training, they can carry out maintenance and repair of various components, so that normal operation of your equipment very quickly, to ensure the fastest solution to your problem. 2, timely telephone technical support - troubleshooting experts to answer your call, provide timely solutions to the problem. 3, National Service Division Jie ------- provide high quality services across the country. 4, flexible --------- phone repair response time after the door in time to solve the problem. , 5, each of the chromatographic free training courses from time to time, the contents of chromatographic theory, analysis, application, technology, equipment operation, troubleshooting and maintenance. Please pay attention. Specific surface area tester Beijing: the specific surface area analyzer, Dongcheng, Xicheng than the surface area analyzer, Chongwen, Xuanwu, Chaoyang, Fengtai, Shijingshan, Haidian, Mentougou surface area analyzer, Fangshan, Tongzhou, Shunyi, Changping surface area analyzer, specific surface area of Daxing detector, the detector surface area of Huairou, Pinggu detector surface area, surface area tester Yanqing and Miyun surface area analyzer. Specific surface area tester Hebei: Shijiazhuang City, surface area analyzer, specific surface area analyzer Tangshan, Qinhuangdao, Handan, Xingtai City, Baoding, Zhangjiakou City, BET surface area analyzer, detector surface area of Chengde City, Cangzhou, Langfang City BET tester, Hengshui City, the specific surface area tester. |
Admin>>>
You are the 22384 visitor
Copyright © GuangDong ICP No. 10089450, Special Technology Development Co., Ltd. Hunan record All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 22384 visitor
Copyright © GuangDong ICP No. 10089450, Special Technology Development Co., Ltd. Hunan record All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
| No.6922944

